<LOGO>
FM Transmitter Measurement Report
Created: 2024-06-06 07-37-01
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 41 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
6 kHz 46 kHz 17932 0,1283
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,9 dBr -0,75 dBr 0,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 7:36, 6.06.2024
RT
"Cesky rozhlas Plus - kdyz chcete vedet proc "
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 46 kHz MIN: 6 kHz % above 77 kHz: 0,1283 Acquired: 2024/06/06 7:36:58 Total samples: 17932 Equivalent time: 0:14:56 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 0,0 dBr MIN: -1,9 dBr AVE: -0,75 dBr % above 0,2 dBr: 0,0 Last value: -1,9 dBr (2024/06/06 7:36:57) 07:24 07:26 07:28 07:30 07:32 07:34 07:36 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality